Subsystem.ResetAllTriggers Method

This method resets all triggers for all kinds of events. If the Subsystem is not started, this method throws an exception of type RTX64Exception containing an explanatory error message. This method can be called when monitoring is stopped or started. It takes effect immediately. If any of the specified triggers are already reset, they remain reset. Triggers do not persist after the RTX64 Subsystem stops. If persistence is desired, it is the client's responsibility to save trigger state before the Subsystem stops and to restore it when the Subsystem starts. This method is thread-safe and executes atomically across all processes with respect to all other trigger-related methods.

Namespace:  IntervalZero.RTX64.Monitor
Assembly:  IntervalZero.RTX64 (in IntervalZero.RTX64.dll) Version: 4.0.0.0 (File version: 4.5.0)

Syntax
public void ResetAllTriggers()

Implements

IMonitorSubsystem.ResetAllTriggers
Exceptions
ExceptionCondition
RTX64Exception Thrown if this method is used without the RTX64 Runtime installed.