RtecatReadAxisCustomInput2

RtecatReadAxisCustomInput2 reads the second custom input variable of an axis.

Syntax

Copy
RTECAT_ERROR RtecatReadAxisCustomInput2(
  [in]    RTECAT_HANDLE Axis,
  [out]   DWORD* pValue
);

Parameters

[in] Axis

A handle to an axis. To retrieve the corresponding handle, use RtecatOpenAxisByIndex or RtecatOpenAxisByLocation.

[out] pValue

A pointer to a variable that stores the second custom input variable of an axis.

Return Values

The function returns an RTECAT_ERROR value. If the function succeeds, it returns ecatErrNoError. If the function fails, it returns a different value.

Possible return values:

Return value Meaning

ecatErrNoError

The function succeeded.

ecatErrNullParameter

Parameter pValue is NULL.

ecatErrWrongParameter

Parameter Axis is invalid.

ecatErrMainDeviceNotReady

The MainDevice is not ready.

ecatErrWrongEnvironment

The link has not started.

ecatErrVariableUnavailable

The device does not support reading the second custom input variable.

Remarks

RtecatReadAxisCustomInput2 is a synchronous function that executes immediately and returns a result upon completion.

Requirements

Minimum supported version Header Library

wRTOS 1.0 SDK

RtecatApi.h

RtecatApi_W64.lib (Windows), RtecatApi.lib (RTSS)

See Also: