RtecatReadAxisMopDisplay

RtecatReadAxisMopDisplay reads the modes of operation display of an axis.

Syntax

Copy
RTECAT_ERROR RtecatReadAxisMopDisplay(
  [in]    RTECAT_HANDLE Axis,
  [out]   BYTE* pValue
);

Parameters

[in] Axis

A handle to an axis. To retrieve the corresponding handle, use RtecatOpenAxisByIndex or RtecatOpenAxisByLocation.

[out] pValue

A pointer to a variable that stores the modes of operation display of an axis.

Return Values

The function returns an RTECAT_ERROR value. If the function succeeds, it returns ecatErrNoError. If the function fails, it returns a different value.

Possible return values:

Return value Meaning

ecatErrNoError

The function succeeded.

ecatErrNullParameter

Parameter pValue is NULL.

ecatErrWrongParameter

Parameter Axis is invalid.

ecatErrMainDeviceNotReady

The MainDevice is not ready.

ecatErrWrongEnvironment

The link has not started.

ecatErrVariableUnavailable

The device does not support reading the modes of operation display.

Remarks

RtecatReadAxisMopDisplay is a synchronous function that executes immediately and returns a result upon completion.

Requirements

Minimum supported version Header Library

wRTOS 1.0 SDK

RtecatApi.h

RtecatApi_W64.lib (Windows), RtecatApi.lib (RTSS)

See Also: