Library.ReloadSubDeviceEEprom Method
Reloads a SubDevice's EEPROM.
Namespace:
IntervalZero.MaxRT.Ecat.Api.NetApi
Assembly:
IntervalZero.MaxRT.Ecat (in IntervalZero.MaxRT.Ecat.dll) Version: 1.0.0.0 (File version: 1.1.0)
Syntax
public CommandStatus ReloadSubDeviceEEprom(
EcatHandle subDevice
)
Parameters
subDevice
Type: EcatHandle
A handle to a SubDevice. To retrieve the corresponding handle, use OpenSubDeviceByIndex, OpenSubDeviceByStationAddress, or OpenSubDeviceByExplicitId.
Return Value
This method returns a CommandStatus class. If an error occurs, property State in CommandStatus is set to ecatCommandError, and the error code is stored in property ErrorId.
Possible errors:
| Error code | Meaning |
|---|---|
|
ecatErrNoError |
The function succeeded. |
|
ecatErrWrongParameter |
Parameter subDevice is invalid. |
|
ecatErrMainDeviceNotReady |
The MainDevice is not ready. |
|
ecatErrWrongSubDeviceState |
The method can't be used in the current SubDevice state. It can only be used in the Init state. |
See Also: